Zipato and the Zipato logo are registered Trademarks. All
other product names mentioned herein may be trademarks or
registered trademarks of their respective companies.
NOTICE
Although Zipato has attempted to ensure the accuracy of the
content of this manual, it is possible that this document may
contain technical inaccuracies, typographical, or other errors.
Zipato assumes no liability for any error in this publication, and for
damages, whether direct, indirect, incidental, and consequential
or otherwise, that may result from such error, including, but not
limited to loss of data or profits. Zipato provides this publication
“as is” without warranty of any kind, either express or implied,
including, but not limited to implied warranties of merchantability
or fitness for a particular purpose. The published information in
the manual is subject to change without notice. Zipato reserves
the right to make changes in the product design, layout, and driver
revisions without notification to its users. This version of the
Installation guide supersedes all previous versions.
ELECTROMAGNETIC COMPATIBILITY
When operated according to manufacturer instructions, the
product complies with all applicable CE harmonised standards
from EMC Directive 2004/108/EC and Part 15 of the FCC Rules.
The connections conducting HF signals must not be damaged or
altered in any way by the user.
TAKE CARE OF YOUR SAFETY
Display extreme caution when using ladders or steps, please
follow manufacturer’s instructions. Be careful when using hand
and power tools and follow the manufacturer’s guidelines when
using them. Take care that the correct tools are used. Wear
goggles or protective clothing where required.
ELECTRICAL SAFETY
All installation and operation here should conform to your
local electrical safety codes. The power shall conform to the
requirement in the SELV (Safety Extra Low Voltage) and the
Limited power source is rated 12V DC in the IEC60950-1.
Please note: Do not connect different power supply to the device
from what you received with your device, it may result in device
damage! We assume no liability or responsibility for all the fires
or electrical shock caused by improper handling or installation.
CAUTION
Do not apply power to the camera before completing installation.
Please install the proper power cut-off device during the
installation connection.
INTRODUCTION
Heavy-duty automated Valve Controller, that can fit variety of fluid
management purposes. When used as a part of Zipato ecosystem, it
can cut the water or gas supply when leak is detected. Additionally,
using Zipato Rule Creator you can make it part of virtually limitless
automation scenarios. Every Valve Controller can work as signal
Weight
Valve: 404g
Packaging: 672g
MODELS AND REGIONS
EUROPE gr-105.eu / 868.42 MHz
RUSSIA gr-105.ru / 869.02 MHz
UNITED STATES gr-105.us / 908.42 MHz
INSTALLATION
01 - Pipe clamp
02 - Mounting hole
03 - Clamp adjuster
04 - Rocker arm
05 - Handle
06 - Clutch
07 - Gas ball valve
FOR GAS DUCTWORK USER
The main ball valve should be designed and installed to the place as
much as convenient for manual opening & closing operation. The
manipulator should keep 20mm away from the wall.
Place the two mounting brackets on each side of the mounting
hole and tighten the screw with a wrench and screwdriver. Adjust
to the pipe and thread the clamp adjuster through the holes on
the mounting brackets and around the pipe. (Use the clutch to
adjust the valve controller rocker arm to proper position) Adjust
the rocker arm of the valve controller upon the water/gas valve
rocker arm and tighten the two screws to make a tight connection.
Tighten the clamp adjuster so that the whole valve controller
assembly is stable and unable to tip on either side. Double check if
anything isn’t tightened properly!
FOR BOTTLED GAS USER
To properly connect the valve controller to the gas canister, the
user first needs to remove the original pressure reducing valve.
Afterwards install a manipulator with the special ball valve for the
pipe, in-between the original valve and the pressure reducing valve.
Tighten properly! Use the following picture as reference.
repeater, therefore all the devices form into cellular network and
generate multi-routes. This product can be included and operated
in any Z-Wave network with other Z-Wave certified devices from
other manufacturers and/or other applications. All non-battery
operated nodes within the network will act as repeaters regardless
of vendor to increase reliability of the network.
OVERVIEW
PACKAGE CONTENT
1PCValve Controller
1PCPower adapter
1PCMounting bracket set
1PCQuick installation guide
FEATURES
Robust, sturdy built valve controller ideal for automated
irrigation scenarios
New Z-Wave 500 series chip
Can be used for automatic control of gas and fluid valves
Cutting the water supply automatically if a leak or flood is
detected (if associated with a flood detector)
Cutting off the gas supply if a leak is detected (if associated with
a gas detector)
Remote control with smartphone or PC
Can be used with various Z-Wave networks/controllers
Manual activation in case of power failure
Installs on a standard 1/4 turn valve
1 Led indicator
Aluminium alloy shell
Easy installation
SPECIFICATION
Protocol
Z-Wave Plus
Rated voltage
12V/1A
Wireless range
40m
Valve pressure
1.6 Mpa
Open time
5 ~ 10 seconds
Close time
5 ~ 10 seconds
Torque
30 ~ 60 kg.cm
Dimensions
Valve: 145x85x74 mm
Packaging: 166x146x102 mm
VALVE
CONTROLLER
QUICK INSTALLATION GUIDE
v1.0
make your home smartwww.zipato.commake your home smartwww.zipato.com
01
01 - Gas cylinder
02 - Controlling manipulator of special ball valve for gas cylinder
03 - Original pressure reducing valve of gas cylinder
04 - Original gas hose and hose clip
05 - Gas apparatus
In case of alarm failure, overhaul or power cut
a | Pull out the tab of clutch and keep,
b | Manually turn the handle to 90 degree, open and close the
handle to the dead point until move smoothly,
c | Release the tab, then gently move the handle to make the clutch
back to its original position.
This product is also applicable to automatic control of other gas or
fluid valves such as water.
Disclaimer: The above information is subject to change without
prior notice. Please contact your local dealer or Manufacturer for
any possible updates.
OPERATION
1 | Add/Delete device
Add/Delete button: the red button on the upper-front side.
Press 3 times to send NIF signal , make sure the Z-Wave
controller in the range for inclusion or exclusion.
Notice: It is recommended to keep the device within 1 meter to
the controller during Add/Delete operation. If the controller has
not received the signal, please repeat again.
2 | Reseting the valve
Press and hold the button for 10 seconds. The device will
send the reset notification to the controller and erases the
device memory.
3 | Association capabilities
When the valve is set into association with other devices it can
send Switch_Binary_reports. Group 1-Lifeline can be set up
and support 5 nodes. ( Group 2~5 is not support)
ZWAVE COMMAND CLASSES
COMMAND_CLASS_BASIC
COMMAND_CLASS_VERSION
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_MANUFACTURE_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GROUPINFO
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_SWITCH_ALL
TROUBLESHOOTING
Having trouble installing your new product?
Zipato’s website contains the latest user documentation and
software updates for Zipato products and services:
www.zipato.com
You can also find answers in the Zipato Community at:
community.zipato.com
Zipato Support: support@zipato.com
LIMITED PRODUCT WARRANTY
GENERAL TERMS
Nothing in this Limited Product Warranty affects your statutory
rights as a consumer.
05
07
06
04
01
03
02
04
05
03
01
02
Veja o manual do Zipato GR-105 aqui, de graça. Este manual está na categoria Não categorizado e foi avaliado por 1 pessoas com uma média de 6.5. Este manual está disponível nos seguintes idiomas: Inglês. Você tem alguma dúvida sobre o Zipato GR-105 ou precisa de ajuda? Faça a sua pergunta aqui
Precisa de ajuda?
Tem alguma pergunta sobre o Zipato e a resposta não está no manual? Faça a sua pergunta aqui Apresente uma descrição clara e completa do problema e da sua pergunta. Quanto melhor descrever o seu problema e a sua pergunta, mais fácil será para outros proprietários da Zipato dar-lhe uma resposta adequada.
Não consegue encontrar a resposta à sua pergunta no manual? Pode encontrar a resposta à sua pergunta nas Perguntas Frequentes sobre o Zipato GR-105 abaixo.
Que certificações tem o/a Zipato GR-105?
O/A Zipato GR-105 tem as seguintes certificações: EMC 2004/108/EC, R&TTE 1995/5/EC, LVD 2006/95/EC, FCC Part 15 - See more at: https://www.zipato.com/product/valve-controller#sthash.ZU9PtVOK.dpuf.
O manual de Zipato GR-105 está disponível em Português?
Infelizmente, não temos o manual para o(a) Zipato GR-105 disponível em Português. Este manual está disponível em Inglês.
Precisa de ajuda?
Tem alguma pergunta sobre o Zipato e a resposta não está no manual? Faça a sua pergunta aqui Apresente uma descrição clara e completa do problema e da sua pergunta. Quanto melhor descrever o seu problema e a sua pergunta, mais fácil será para outros proprietários da Zipato dar-lhe uma resposta adequada.
Número de perguntas: 0